BFFSH - SEALER EC-1293B

  • MSDS: BFFSH
  • Manufacturer: AC AND S DIV 3M COMPANY
  • Product Name: SEALER EC-1293B
  • National Stock Number: 8030-00-576-8360
Product Identification

Product ID:SEALER EC-1293B
MSDS Date:01/01/1985
FSC:8030
NIIN:00-576-8360
MSDS Number: BFFSH

Responsible Party
AC & S DIVISION, 3M COMPANY

Emergency Phone: 612-733-1110

Cage: 76381

Contractor
MINNESOTA MINING AND MFG CO, DBA 3M
SAINT PAUL, MN 55144-1000 US

Telephone: 866-556 5712 / 612-733-1110

Cage: 76381

Ingredients

TITANIUM DIOXIDE

CAS: 13463-67-7

RTECS: XR2275000

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST; 9293


SILICA, AMORPHOUS, DUST

CAS: 112945-52-5

RTECS: VV7310000

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3; 8990


POLYSULFIDE ELASTOMER

Hazards

Effects of Overexposure:EYE IRRITATION. SKIN & INGESTION HAZARD NOT
EXPECTED.

First Aid

First Aid:EYES: FLUSH WITH WATER FOR 15 MINUTES. CALL PHYSICIAN IF
IRRITATION PERSISTS.

Fire Fighting

Flash Point:200F; 93C
Extinguishing Media:CO*2, FOAM, DRY CHEMICAL
Fire Fighting Procedures:NONE
Unusual Fire/Explosion Hazard:NONE

Accidental Release

Spill Release Procedures:COLLECT SPILLED MATERIAL. PLACE IN A METAL
CONTAINER. OBSERVE PRECAUTIONS.

Handling

Other Precautions:DO NOT BREATHE VAPORS DURING CURING OF MIXED SEALER.

Exposure Controls

Respiratory Protection:N/A (MFR)
Ventilation:MECH VENT RECOMND TO KEEP < TLV. VENT CURING OVENS
OUTDOORS.
Eye Protection:SAFETY GLASSES
Supplemental Safety and Health
ALL INGREDIENTS EQUAL 100% WHEN COMBINED PART B OF TWO PART KIT.
CONTAINER SIZE-1 GAL KIT.KEY1:N1.

Chemical Properties

HCC:N1
Spec Gravity:1.6
Solubility in Water:V. SLIGHT
Appearance and Odor:WHITE PASTE, STRONG SULFUR ODOR
Percent Volatiles by Volume:< 1

Stability

Stability Indicator/Materials to Avoid:YES
Hazardous Decomposition Products:CO, CO*2 & SO*2 WHEN SUBJECTED TO
EXCESSIVE HEAT & FLAMES.

Disposal

Waste Disposal Methods:MANUFACTURER RECOMMENDS COMMERCIAL INCINERATION
WITH DESTRUCTION & REMOVAL EFFICIENCY >99.99% IS PREFERRED.
OTHERWISE, DISPOSE IN A LANDFILL OR MUNICIPAL REFUSE INCINERATOR.
DISPOSAL METHODS MUST BE I AW FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.